| Technical Data |
DNA03 |
DNA10 |
| Area
of use: |
- measurements of heights, height
differences, and stakeouts.
- 1st and 2nd order leveling.
- Precision measurements.
|
- measurements of heights, height
differences, and stakeouts.
- Cadastral leveling.
- Technical leveling.
|
| Accuracy: |
Standard
deviation height measurement per 1 km
double run (ISO17123-2) |
Electronic
measurements:
- with invar staffs.
- with standard staffs.
|
0.3mm
1.0mm
|
0.9mm
1.5mm
|
| Optical
measurements: |
2.0mm |
2.0mm |
| Standard
deviation distance
measurement (electronic) |
1cm/20m (500ppm) |
| Range: |
| Electronic
measurement |
1.8m -
110m |
| Optical measurement |
from 0.6m |
| Electronic
Measurement: |
| Resolution
height measurement |
0.01mm,
0.001ft, 0.0005inch |
0.01mm,
0.001ft |
| Time for single
measurement |
Typically
three (3) seconds |
| Measurement
modes |
Single,
average, median, and repeated single
measurements |
| Measurement
programs: |
Measure and record,
staff height/distance, BF, aBF, BFFB,
aBFFB |
| Coding: |
Remark,
free code, and quick code |
| Data Storage: |
| Internal memory |
6000
measurements or 1650 stations |
| Backup |
PCMCIA
card (ATA Flash / SRAM)
SRAM compatible with Omnidrive MCR4 |
| Online operations |
GSI
format via RS232 |
Data exchange
internal
memory |
GSI8 /
GSI16 / XML / flexible formats |
| Telescope
magnification: |
24x |
| Compensator: |
| Type |
Pendulum
compensator with magnetic dampening |
| Slope range |
+/-10' |
| Calibration range |
0.3" |
0.8" |
| Display: |
LCD,
8 lines at 24 characters |
| Battery
operated: |
| GEB111 |
12h operation |
| GEB121 |
24h operation |
| GAD39 (Battery
adapter) |
Alkaline
battery, 6x LR6/AA/AM3, 1.5V |
| Weight: |
2.8kg
(including battery GEB111) |
| Environmental
conditions: |
| Working temperature |
-20ºC to +50ºC |
| Storage temperature |
-40ºC to +70ºC |
| Dust/water (IEC60529) |
IP53 |
| Humidity |
95%, noncondensing |